HANZA
Wavecontrol

Electromagnetic field measurement solutions.

EMF meters

SMP3

SMP3

Portable EMF meter: spectrum analysis, broadband and static field measurement in one unit.

Frequency range
Broadband: DC to 90 GHz. Spectrum analysis: DC to 10 MHz
Weighted Peak Method
Real-time comparison to limits, shown as a percentage
Peak detection
Signals down to 1 µs
Standards
2013/35/EU, ICNIRP, IEC, EN, IEEE, SC6
Connectivity
USB-C and fibre optic
Software
PC software for data download, automatic reporting and remote control
SMP3-Streamer

SMP3-Streamer

Real-time EMF measuring system for automotive human-exposure testing.

Frequency range
1 Hz to 400 kHz (magnetic field)
Probes
WP10M, WP400, WP400-3, WP400c, WPH-DC
Simultaneous
Up to 7 devices
Standards
GB/T 37130, TSC 7048G and others
Result
Real-time PASS/FAIL indication
Data
Excel-type summary file and raw data export
Wavecontrol field probes

Field probes

Isotropic (3-axis) E and H field probes for the SMP3, ISO 17025 calibrated.

Range
DC to 90 GHz
Field
Electric (E) and magnetic (H)
Response
Isotropic, 3-axis
Calibration
ISO 17025
Electric field (E)Magnetic field (H)E and H
DC1 Hz10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz10 MHz100 MHz1 GHz10 GHz100 GHzStatic magnetic fieldWPH-DCDC to 40 kHzLow frequencyWP5010 Hz to 3 kHzWP4001 Hz to 400 kHzWP400-31 Hz to 400 kHzWP400c1 Hz to 400 kHzWP10M1 Hz to 10 MHzHigh frequencyWPF3100 kHz to 3 GHzWPF6100 kHz to 6 GHzWPF8100 kHz to 8 GHzWPF181 MHz to 18 GHzWPF401 MHz to 40 GHzWPF601 MHz to 60 GHzWPF60s1 MHz to 60 GHzWPF9030 MHz to 90 GHzMagnetic fieldWPH60300 kHz to 60 MHzWPH100030 MHz to 1000 MHz

Personal monitors

WaveMon RF-8

WaveMon RF-8

Personal exposimeter: E-field up to 8 GHz, H-field up to 1 GHz.

Frequency
E-field: up to 8 GHz. H-field: up to 1 GHz
Standards
Weighted response for ICNIRP, 2013/35/EU, FCC, SC6 (2015); ITU-T K.145
Alarms
Audible, visual and vibration
Memory
Datalogger, USB download
Power
2 AA batteries
WaveMon RF-60

WaveMon RF-60

Personal exposimeter: E-field up to 60 GHz, H-field up to 1 GHz.

Frequency
E-field: up to 60 GHz. H-field: up to 1 GHz
Standards
ICNIRP, 2013/35/EU, FCC, SC6 (2015), NATO, ARPANSA; ITU-T K.145
Alarms
Two independently configurable over-exposure alarms
Immunity
Up to 30 kV/m at 50/60 Hz
Power
2 AA batteries, over 200 hours
WaveMon LF-400

WaveMon LF-400

Personal exposimeter for low-frequency magnetic fields, DC to 400 kHz.

Frequency
H/B-field: 0 Hz to 400 kHz
Sensors
Hall-effect sensor for static fields, coil sensor for low frequency
Standards
ICNIRP, 2013/35/EU, IEEE; others on request
Alarms
Two alarms, for general public and occupational limits
Power
2 AA batteries

Area monitors

MonitEM

MonitEM

Continuous 24/7 outdoor EMF monitoring around telecom facilities and other sources.

Protection
IP66
Standard
ITU-T K.83
Power
AC, battery and solar panel
Connectivity
Built-in GPRS/3G modem
Probes
WPF3 to WPF90, WPH60, WPH1000
Software
Control Center (optional)
MonitEM-Lab

MonitEM-Lab

Indoor RF monitoring with real-time alarms for labs and production centres.

Standard
ITU-T K.3
Alarms
Email via Control Center, internal audible and visual alarm
Thresholds
User-defined
Connectivity
Ethernet
Probes
WPF3, WPF6, WPF8, WPF18, WPF40, WPF60, WPF90, WPH1000
MonitEM-IoT

MonitEM-IoT

Plug-and-play sensor for 24/7 RF monitoring: exposure becomes real-time data.

Frequency
Up to 8 GHz, electric field isotropic sensor
Connectivity
LTE-M / NB-IoT
Power
Battery, over 3 years
Protection
IP65
Size and weight
25 cm, 555 g
Standards
ITU-T K.83, ICNIRP 2020
MapEM

MapEM

Vehicle-mounted system that records georeferenced exposure levels to create large-area EMF maps.

Platform
MonitEM device in a vehicle, MapEM Reader software
Records
Date/time, GPS position, NIR level
Standard
ITU-T K.113
Protection
IP66
Wavecontrol calibration

Calibration

LabCal: accredited calibration of E and H field probes at Wavecontrol's laboratory in Barcelona.

Accreditation
ISO/IEC 17025, ENAC (Spain)
Range
From 0 Hz up to 90 GHz. Complete solution DC to 40 GHz, extended 40 to 90 GHz
Experience
Over 10,000 accredited calibrations
Recognition
In most countries under ILAC mutual recognition agreements
LabCal Wavecontrol calibration facilities

Contact

Address
Azure Business Center, 24th Floor, Office 6, Baku, Azerbaijan